No.PMA2135
The peak intensity of a flash lamp is much higher than a continuous light source. The PMA2135 detector captures the peak intensity and displays it on the PMA2100 every five seconds. In addition to the peak intensity, the PMA2135 integrates and stores a single pulse dose. The peak intensity of the radiation is displayed in mW/cm2 or W/cm2. The full scale is specified by the customer at the time of ordering. The dose full scale is mJ/cm2 or J/cm2. The photodetector has an active area of 0.474 square inches. The PTFE hemispherical photopic detector has an excellent cosine response, which allows accurate measurement of point or long light sources.
GET A QUOTE
  • Flash detector
  • 产品详情

  • Contact Us

Instrument Introduction:
The spectral response of the human eye changes with light intensity. The human eye has two specific spectral responses, defined by the brightness of the light entering the eye. The first spectral response occurs under normal daytime lighting conditions (photopic), i.e. light intensities above 0.1 Lux. The second spectral response occurs under low light conditions (scotopic), i.e. light intensities between 0.0001-0.001 Lux. Light intensities less than 0.0001 Lux are difficult for the human eye to detect. The shift of the human eye from photopic to scotopic response is called the Purkinje Shift. This detector is an ideal test tool for flash lamps used in the curing industry.
The peak intensity of a flash lamp is much higher than a continuous light source. The PMA2135 detector captures the peak intensity and displays it on the PMA2100 every five seconds. In addition to the peak intensity, the PMA2135 integrates and stores a single pulse dose. The peak intensity of the radiation is displayed in mW/cm2 or W/cm2. Full scale is specified by the customer at the time of ordering. Dose full scale is mJ/cm2 or J/cm2. The photodetector has an active area of 0.474 square inches. The PTFE hemispherical photopic detector has an excellent cosine response, which allows accurate measurement of point or long light sources.

Technical parameters:

· Spectral response follows the CIE photopic spectral luminous efficiency curve (400-700nm) Figure 1 (Photopic efficiency and detector response)

Angular response 5% for angles <60°

Range specified by user - W/cm2 or mW/cm2 J/cm2 or mJ/cm2

· Display resolution Range/104 mW/cm2 or W/cm2 Range/104 mJ/cm2 or J/cm2

Operating environment: 15 to 140 °F (-10 to +60 °C) with no precipitation

Cable 3ft.

1.6" (40.6 mm) diameter

Height 1.8" (45.8 mm)

Weight: 10 oz. (284 grams)

Key Features:
Capture peak irradiance and available energy

· Radiation unit display

Excellent long-term stability

Cosine correction

NIST traceable calibration