Solar Light's GLM10 is designed specifically for continuous monitoring of germicidal lamp output in water contact containers. The GLM10 ensures that the germicidal lamp output is effective and safe to sterilize the water.
Product Description: UV water disinfection systems are really just the effectiveness of the germicidal lamps. Even the best UV water treatment systems will show a noticeable decrease in effectiveness over time due to lamp age and external contamination that reduces the output of the germicidal lamps. Solar Light's GLM10 is designed specifically for continuous monitoring of germicidal lamp output in water contact containers. The GLM10 ensures that the germicidal lamp output is effective and safe to sterilize the water. The GLM10 can be mounted at the working port of the irradiation chamber and the built-in sensor probe will monitor the lamp. The GLM10 is designed to display 0-100% intensity values. When a new bulb is installed, it is easily calibrated to 100%. As the bulb ages and buildup builds up, the display will accurately show the current bulb intensity as a percentage. A maximum threshold can be preset, and when the preset threshold is reached, the fault display lamp for automatic value control and remote warning as well as the internal relay are activated to ensure a continuous supply of safe drinking water.
Technical parameters:
Current requirement 115VAC 60Hz
Display resolution 1%
Range 0 - 100%
Relay contacts
10A 125VAC Form C Factory set, normally closed or normally open
show Red LED display, 0.56" high
Detector Port 1" FPT (Other sizes available)
Weight 1.5 lbs. (680 grams)
Dimensions 4 5/8" x 3 1/8" x 5" (11.7 x 7.9 x 12.7 cm)
Pressure 150 PSI / 1034 kPa
Wavelength response 240 - 275 nm
Key Features:
Continuous Monitoring
Easy one-step calibration
Large LED display
Fault indicator
Automatic control of external AC power supply equipment
Shanghai Sales + Technical Support + After-sales Service Center Rayscience Optoelectronic Innovation Co., Ltd address: 4th Floor, Building 122, Lane 2338, No. 1 Duhui Road, Minhang District, Shanghai Telephone: 021-34635258 021-34635259 fax: 021-34635260 E-mail: saleschina@rayscience.com